EasyManua.ls Logo

Baumuller BM4400 - Electrical Data BM446 X Universal Units

Baumuller BM4400
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
79
of 358
3
3.4.1.6 Electrical data BM446X universal units
BM4462 BM4463 BM4466
14) 16)
Rated input power
1)2)
164 kVA 204 kVA 238 kVA
Rated input current
1)2)
(I
eff
) 237 A 295 A 344 A
Total harmonic distortion input current
1)2)
(THD
I
) 43 % 50 % 50 %
Input current max.
2)
(I
eff
) 320 A 395 A 455 A
Rated DC link voltage
1)
540 V
DC
DC link capacity (internal) 6000 F 13200 F
DC link capacity (external), permitted see ZPage 227
DC link discharging time (internal DC link capacity) 150 s 280 s
Waiting period between two power up processes none
Output voltage
1)3)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
12)
0 Hz to 450 Hz
Rated output current
1)5)6)7)15)
(I
AC
) at 4 kHz
4)
250 A 300 A 350 A
Rated output current
1)5)6)7)15)
(I
AC
) at 8 kHz
4)
200 A 240 A 240 A
Output peak current
1)5)6)8)15)
(I
AC
) at 4 kHz
4)
325 A 390 A 450 A
Output peak current
1)5)6)8)15)
(I
AC
) at 8 kHz
4)
260 A 312 A 312 A
Max. peak current period
8)
60 s
Power input DC link terminals
max. 160 kW
Brake resistor current, permitted (Î) max. 230 A max. 236 A
Brake resistor external 3.4
3.33
Brake resistor threshold (Û)
11)
780 V
Brake resistor peak power 179 kW 183 kW
Permitted continuous power
brake resistor external
130 kW
Power loss referring to
power input 3960 W 4800 W
Power input referring to control voltage max. 80 W
Power input of the device fan referring
to 230 V
AC
9)
174 W
Current of integrated brake control max. 8.0 A
10)
Cooling air requirement power heat sink 400 m
3
/h
Cooling air requirement device internal space 200 m
3
/h

Table of Contents