Controller terminals
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07 Baumüller Nürnberg GmbH
218
of 358
7.11
7.11.2 Analog input slot/position D and E
NOTE!
The module AIO-01 is always integrated in ES controller (position E, connector X4).
The module AIO-02, 03 or 04 can be ordered at position D.
The module BM4-F-AIO-01 can be plugged in slot E in standard controller. The mod-
ule BM4-F-AIO-02, 03 or 04 can be plugged in slot D or E.
NOTE!
Choose position E in ProDrive for configuration of analog inputs/outputs AIO-01 (con-
nector X4)in ES controller.
Further information referring to analog inputs/outputs, see manual BM4-F-AIO-XX
(5.01045).
Pin assignment Pin No. Pin assignment
D-sub male terminal 9-pin
1 IN 1 +
2 IN 2 +
3 OUT 1 - , OUT 2 -
4 OUT 1 +
5 OUT 2 +
6 IN 1 -
7 IN 2 -
8 OUT 1 - , OUT 2 -
9 OUT 1 - , OUT 2 -
Max. cross-section
of connection
Connection technology
0.25 mm
2
D-sub female, 9-pin,
metal type or metalized