Technical Data
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
63
of 358
3
3.4 Electrical data basic units
3.4.1 Electrical data of the universal units
3.4.1.1 Electrical data BM441X universal units
BM4412-
XTX
BM4413-
XTX
BM4414-
STX
9)
BM4414-
CTX
8)9)
Rated input power
1)
1.9 kVA
3.3 kVA
5.1 kVA
6.9 kVA
Rated input rated current
1)
(I
eff
) 2.8 A 4.8 A 7.3 A 10.0 A
Total harmonic distortion input current
1)
(THD
I
) 119 % 110 % 109 % 113 %
Current input max. (I
eff
) 5.2 A 9.0 A 20.0 A 20.0 A
DC link rated voltage
1 )
(U
DC
) 540 V
DC
DC link capacity (internal) 110 F
240 F
330 F
330 F
DC link discharge time
(internal DC link capacity)
80 s
175 s
240 s
240 s
DC link capacity (external), permitted see ZF
igure 32– on page 65
Period between two power up processes
12)
at least 60 s
Output voltage
1)2)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
12)
0 Hz to 450 Hz
Rated output current
1)4)5)6)13)
(I
AC
) at 4 kHz
3)
2.5 A 4.5 A
5.5 A 7.5 A
Rated output current
1)4)5)6)13)
(I
AC
) at 8 kHz
3)
2.5 A 4.5 A
5.0 A 5.0 A
Output peak current
1)4)5)7)13)
(I
AC
) at 4 kHz
3)
5.0 A 9.0 A
20.0 A 20.0 A
Output peak current
1)4)5)7)13)
(I
AC
) at 8 kHz
3)
5.0 A 9.0 A
12.0 A 12.0 A
Max. peak current period
7)
60 s 1 s
Power input DC link terminals
10)
max. 2.0 kW max. 3.0 kW max. 4.3 kW
Brake resistor current, permitted (Î) max. 5.9 A
max. 12.0 A
Brake resistor external 130 65
Brake resistor threshold (Û) 780 V
Brake resistor peak power 4.5 kW 5.0 kW 9.4 kW 9.4 kW
Permitted continuous power
brake resistor external
1.0 kW 1.5 kW 3.0 kW 3.0 kW
Power loss referring to
power input 33 W 60 W 80 W 102 W
Power input referring to control voltage max. 60 W
Current of the integrated brake connection max. 0.5 A max. 1.0 A