Baumuller BM4400 - Electrical Data BM4632 Acceleration Units

Baumuller BM4400
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
85
of 358
3
3.4.2.1 Electrical data BM4632 acceleration units
BM4632
Rated input power
1)2)
36,7 kVA
Rated input current
1)2)
(I
eff
) 53,0 A
Distortion factor of the
input current
1)2)
(THD
I
) 57 %
Input current, max.
2)
(I
eff
) 128 A
DC link rated voltage
1)
540 V
DC
DC link capacity (internal) 3000 F
DC link capacity (external), permitted see ZPage 227
DC link discharging time (internal DC link capacity) 140 s
Waiting time between two power up processes no
Output voltage
1)3)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
10)
0 Hz to 450 Hz
Rated output current
1)5)6)7)12)
(I
AC
) at 4 kHz
4)
60 A
Rated output current
1)5)6)7)12)
(I
AC
) at 8 kHz
4)
48 A
Output peak current
1)5)6)8)12)
(I
AC
) at 4 kHz
4)
120 A
Output peak current
1)5)6)8)12)
(I
AC
) at 8 kHz
4)
96 A
Max. peak current period
8)
1,25 s
Power input DC link terminals
9)
max. 10,0 kW
Brake resistor current, permitted (Î) max. 70,0 A
Brake resistor external 11
Brake resistor threshold (Û) 780 V
Brake resistor peak power 56 kW
Permitted continuous power brake resistor external 10 kW
Power loss referring to
power input 840 W
Power input referring to control voltage max. 88 W
Current of integrated brake control max. 8 A
11)
Cooling air requirement device internal space 60 m
3
/h
Requirements to water
cooling see ZPage 61