EasyManua.ls Logo

Baumuller BM4400 - Application Expansions; C.3.5 Application Expansions

Baumuller BM4400
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safe stop
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07 Baumüller Nürnberg GmbH
346
of 358
C.3
C.3.5 Application expansions
The safety function „Safe stop“ is provided via three independent switch off channels and a
hardware pulse enable input (category 4 according to EN ISO 13849-1) at the b maXX 4000
converter (BM4X3X-XX2 to BM4X7X-XX2).
However, in many ranges it is not required to operate „Safe Stop“ in category 4.
In the following, application examples are viewed, at which only two of the three switch off chan-
nels are used.
m Applic
ation example 1
Application example for machine of category 3 with h
ardwired pulse enable input and process
data communication via a field bus.
Switching off occurs by means of safety relay 1 and safety relay 2.
Figure 117: Version with two safety relays (BM4XXX-XX2)
Herd the hardware pulse enable input (X3:5) is hardwired. The activation of the „Safe Stop“ is
made with two channels via the safety relay 1 and 2 (X102:3 / X103:3).
The release of the converter and the process data communication is made via field bus.

Table of Contents