EasyManua.ls Logo

Baumuller BM4400 - Coherence between Rated Current and Peak Current; Calculation of the Thermal Rms Current; Coherence between Peak Current and Rated Current

Baumuller BM4400
360 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
59
of 358
3
3.3.6 Coherence between rated current and peak current
m Calculation of the thermal rms current from the dimensioning cycle
i(t)
I
1
I
2
I
3
T
t
t
1
t
2
t
3
I
1
I
2
I
3
t
1
t
2
t
3
Figure 28: Calculation of the thermal rms current
I
eff
I
n
2
t
n
T
----
n1=
k
I
1
2
t
1
T
---- I
2
2
t
2
T
---- I
3
2
t
3
T
----
++==
m Coherence between peak current and rated current
for the dimensioning of a motion cycle
i(t)
I
peak
T
t
t
peak
I
peak
T + t
peak
Figure 29: Coherence between peak current and rated current

Table of Contents