Accessories and Spare Parts
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
271
of 358
11
5)
Connection lugs (current bars). Position see ZFigure 87– on page 186
Screw maximum two cable lugs to the current bar - one on the front side, one on the
reverse side of the bar.
6)
Connection lugs (current bars). Position see ZFigure 90– on page 189
At a connection cross-section of 95 mm
2
, cable lug width max. 25 mm:
Screw maximum two cable lugs to the current bar - one on the front side, one on
the reverse side of the bar.
At a connection cross-section of 185 mm
2
, cable lug width max. 35 mm:
Screw two cable lugs to the current bar at maximum- one on the front side, one on
the reverse side of the bar.
11.1.3 Cable control voltage supply/signals
Cross section
1)
1.5 mm
2
Maximum length
2)
user-defined
Connection to device with /without wire
end ferrules (plug-in terminal)
1)
The installing of the cables is user-defined.
2)
The length of the cable has no influence on the compliance to the EMC regulation.