Troubleshooting and fault correction
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
231
of 358
9
Position controller Position deviation dynamic - X X - SH P1054 P1050
Position deviation static - X X - SH P1055 P1050
Digital output Short-circuit digital output - X - - - - -
Controller
synchronizing
Controller not synchronous with external
signal
X X X X
4)
P0533 P0299
Encoder 1 Cable break - X - - IS - -
Cable break (sin
2
+ cos
2
) - X - - IS - -
Overspeed - X X - IS P1072 -
Encoder 2 Cable break - X - - IS - -
Cable break (sin
2
+ cos
2
) - X - - IS - -
Overspeed - X X - IS P1082 -
Ramp-up
option modules
Error at module initialization - X X - IS P0838 P0838
Cyclical set value trans-
mission to the optional
modules
Transmission timeout - X X X
5)
P0839 P0298
Safety relay Supply voltage is missing or
safety relay faulty
- X - - IS - -
Safety relay - warning X - - - - - -
Blocking monitoring Drive blocked - X X - IS P1260 P1260
Monitoring function Warning/error
Warning
Error
Threshold adjustable
Reaction adjustable
Reaction
Adjusting of
limit in parameters
Activation by
parameter
1)
Not available at BM441X and BM442X
2)
Pulse inhibit is generated after adjustable time period
3)
Only when using the KTY sensor
4)
Adjustable with P0299
5)
Adjustable with P0298
6)
Not available at power modules
IS: Pulse inhibit
SH: Quick stop
X: implemented