Technical Data
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
71
of 358
3
1)
All rated values refer to a DC link voltage of 540 V, a control voltage of 24 V and an environmental temperature of 40 °C.
2)
Using the power choke listed in ZPower chokes– on page 300 at a power supply with U
K,power supply
= 0.4 %.
3)
The output voltage is a pulsed DC voltage. The operating range refers to the RMS of the fundamental wave.
U
AC
3 0 V to 3
U
DC
2
----------- 10 V–
=
without overmodulation of the PWM.
4)
Switching frequency of the inverter (adjustable).
5)
RMS at an environmental temperature of 40 °C.
6)
At rated power supply voltage the unit supplies rated / maximum output currents. With input voltages above the rated power supply
voltage the output currents must be reduced at constant output power.
Output current [%]
Derating of output current
BM4X32
Power supply voltage [V]
Output current [%]
Derating of output current
BM4433
Power supply voltage [V]
Output current [%]
Derating of output current
BM4434
Power supply voltage [V]
Output current [%]
Derating of output current
BM4435
Power supply voltage [V]
Figure 35: Derating the output current BM443X universal units
7)
The input current must be reduced between 40 °C and 55 °C. See correction factors at changed operating conditions ZEnvironmental
temperature– on page 57.
8)
The peak output current is supplied for the maximum peak current period for the motor at the first acceleration (cold power unit). The in
fact possible overload time is dependent on the preload of the device and on the heat sink temperature, it is determined by the overload
monitoring of the device.
9)
The sum of the mean effective power, which is transmitted via the DC link terminals and the mean effective power at the motor terminals,
may not exceed the specified value continuously.