*RST Value
MINimum
Example POW 10
Query Syntax [SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude]?
Query Response <NR2>
7.17 [SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude] <NRf+>
This command is used to set the resistance setting in CR mode.
Command Syntax [SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Parameters MIN MAX- MINimum- MAXimum
Unit
ohm
*RST Value
MAXimum
Example RES 5
Query Syntax [SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]?
Query Response <NR2>
7.18 [SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]?
This command is used to query the resistance setting in CR mode.
Command Syntax [SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]?
Parameters None
Unit
ohm
*RST Value
MAXimum
7.19 [SOURce:]DYNamic:HIGH[:LEVel] <NRf+>
This command is used to set the high-level load current in dynamic mode.
Command Syntax [SOURce:]DYNamic:HIGH[:LEVel] <NRf+>
Parameters MIN MAX- MINimum- MAXimum
Unit
A
*RST Value
0
Example DYN:HIGH 10