12.38 Set/Read software OPP delay time. (88H/89H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command (88H/89H
4 OPP delay time
5-25 Reserved
26 Checksum
12.39 Set/Read the rst measured point. (8AH/8BH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 8AH/8BH
4-7 The rst measured value (Low byte to High byte order)
8-25 Reserved
26 Checksum
12.40 Set/Read the second measured point. (8CH/8DH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 8CH/8DH
4-7 The second measured value (Low byte to High byte order)
8-25 Reserved
26 Checksum
12.41 Set/Read Vd value in CR-LED mode. (8EH/8FH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 8EH/8FH
4-7 Vd value (Low byte to High byte order)
8-25 Reserved
26 Checksum