53
12.34 Set/Read OCP value. (80H/81H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 80H/81H
4-7 OCP value (Low byte to High byte order)
8-25 Reserved
26 Checksum
12.35 Set/Read OCP delay time. (82H/83H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 82H/83H
4 Delay time
5-25 Reserved
26 Checksum
12.36 Enable/Disable OCP function. (84H/85H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 84H/85H
4 Set OCP state (0:o 1:on)
5-25 System reverse
26 Checksum
12.37 Set/Read software OPP value. (86H/87H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 86H/87H
4-7 Software OPP value (Low byte to High byte order)
8-25 Reserved
26 Checksum