12.15 Set /Read the list operation mode (CC) 3AH/3BH
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 3AH/3BH
4 LIST operation mode 0 is CC mode
5-25 byte Reserved
26 Checksum
12.16 Set/Read the list repeat mode. (3CH/3DH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 3CH/3DH
4 LIST repeat operation mode (0 is ONCE, 1 is REPEAT, 65535 represents no limit)
5-25 Reserved
26 Checksum
12.17 Set/Read list step counts. (3EH/3FH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 3EH/3FH
4-5 LIST steps count
6-25 Reserved
26 Checksum
12.18 Set/Read one of the step’s current and time values. (40H/41H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 40H/41H
4-5 Appointed one step
6-9 Current value of current step (Low byte to High byte order)
10-11 Time value of current step (Low byte to High byte order) (1 represent 0.1mS)
12-25 Reserved
26 Checksum