Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 5BH/5CH
4 Storing area
5-25 Reserved
26 Checksum
12.28 Selecting/Reading FIXED/SHORT/TRAN/LIST/ BATTERY function mode. (5DH/5EH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 5DH/5EH
4 Work mode (0:FIXED, 1:SHORT, 2:TRANSITION, 3:LIST, 4: BATTERY)
5-25 Reserved
26 Checksum
12.29 Read input voltage, current, power and relative state. (5FH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 5FH
4-7 Actual input voltage value (Low byte to High byte order)
8-11 Actual input current value (Low byte to High byte order)
12-15 Actual input power value (Low byte to High byte order)
16 Operation state register
17-18 Demand state register
19-25 Reserved
26 Checksum
12.30 Operation status register