55
12.42 Clear protection state. (90H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 90H
4-25 Reserved
26 Checksum
12.43 Enable/Disable voltage autorange function. (91H/92H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 91H/92H
4 Auto voltage range state (0:o 1:on)
5-25 Reserved
26 Checksum
12.44 Enabel/Disable CR-LED function. (93H/94H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 93H/94H
4 CR-LED mode (0: OFF 1:ON)
5-25 Reserved
26 Checksum
12.45 Send a trigger signal. (9DH)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command 9DH Regardless of the current trigger souce it is, this command can provide a trigger signal
4-25 Reserved
26 Checksum