60
12.62 Set/Read the voltage upper limit in CR mode. (C2H/C3H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command C2H/C3H
4-7 The voltage upper limit (Low byte to High byte order)
8-25 System reserve
26 Checksum
12.63 Set/Read the voltage lower limit in CR mode. (C4H/C5H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command C4H/C5H
4-7 The voltage lower limit (Low byte to High byte order)
8-25 System reserve
26 Checksum
12.64 Set/Read the current range in list mode. (C6H/C7H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command C6H/C7H
4-7 Current range (Low byte to High byte order)
8-25 System reserve
26 Checksum
12.65 Set/Read autotest steps. (D0H/D1H)
Byte Description
1 AAh
2 Address (0-31, 0XFF)
3 Command (D0H/D1H
4-5 Autotest steps (Low byte to High byte order), when one step is selected, then corresponding bit should be set to
1.
6-25 Reserved
26 Checksum