Page #70 background image
70 en | Dial-Up Networking Access Easy Controller
Ver 2.0.0 | 2006.07 Hardware Manual Bosch Security Systems
10.5 Handling of IP Addresses by Access Easy Controller
When dial-up networking is used to connect to the Access Easy Controller, the connection is
made using a communication point-to-point protocol (PPP). The PPP protocol is used when-
ever a computer establishes a dial-up connection to any server. In the case of Access Easy
Controller, the controller acts as the server and established the PPP connection to the cus-
tomer's computer.
When a dial-in session is started, the server assigns an IP address to the computer that has
dialled-in and requested the session. In our case, the server is the Access Easy Controller.
The IP address that is assigned to the computer making the dial-in request is obtained from a
database parameter in Access Easy Controller, which can be managed as necessary from the
Panel Admin, Panel Setup section of the database.
Normally, the dial-up IP address is managed automatically by Access Easy Controller based on
the network address that is assigned to the controller during the installation and setup pro-
cess. If the controller is assigned a Class A network address, then the controller will automat-
ically configure the dial-in IP address to a Class C address. If the controller is assigned a
Class B or Class C network address, then dial-up networking will automatically be configured
to a Class A address. In most cases, the different class of the dial-in IP address will prevent
any conflict or duplication of IP addresses within the customer's network.
10.6 Changing the Dial-In IP Address
Normally, the dial-in IP address is managed automatically by the controller and will never need
to be changed by the user. A possibility exists, however, that the automatically assigned dial-
in IP address could conflict with another computer on the customer's network. In that cause,
it will be necessary to modify the default dial-in IP address.
To change the dial-in IP address, connect to the Access Easy Controller over the network and
login. Then go the Panel Admin, Panel Setup and select the Dial In IP Settings hot link. Mod-
ify the IP address and save the change.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Access Easy Controller and is the answer not in the manual?

Bosch Access Easy Controller Specifications

General IconGeneral
BrandBosch
ModelAccess Easy Controller
CategoryIP Access Controllers
LanguageEnglish

Related product manuals