D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 113
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
L## C Function 128 [through 143]
Execute the desired Custom Function.
3.12.8 Report Levels
L## Force Arm
A user with this authority level can Force Arm.
L## Area O/C
Generates Opening and Closing Reports if the area where this authority level is assigned
sends Opening and Closing Reports.
L## Restricted O/C
Generates an Opening Report if a bell is ringing or a Closing Report when force or bypass
arming. The area where this authority level is assigned must be programmed for restricted
openings and closings (refer to the A# Restrictd O/C prompt in Section 3.10.4 Open/Close
Options, page 69.
L## Perimeter O/C
Generates Perimeter Opening and Closing Reports if the area where this authority level is
assigned sends Perimeter Opening and Closing Reports. Refer to the A# Perimeter O/C
prompt in Section 3.10.4 Open/Close Options, page 69.
L## Send Duress
Generates a Duress Report if the area where this authority level is assigned sends duress.
(Refer to the A# Duress Enable prompt on in Section 3.10.4 Open/Close Options, page 69.)
L## Passcode Arm
Arm an area by entering a passcode and pressing [ENTER].
L## Passcode Disarm
Disarm an area by entering a passcode and pressing [ENTER].
Default: Authority Levels 1: Enabled (E)Authority Levels 2-15: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
128 through 143 Enable Custom Function
128 through 143
(Menu function only)
Default: Authority Levels 1-6: Enabled (E)Authority Levels 7-15: Blank (-)
Selection: - or E
Default: Authority Levels 1-14: Enabled (E)Authority Level 15: Blank (-)
Selection: - or E
Default: Blank
Selection: - or E
Default: Authority Levels 1-14: Enabled (E) Authority Level 15: Blank (-)
Selection: - or E
Default: Authority Levels 1-14: Enabled (E)Authority Level 15: Blank (-)
Selection: - or E
Default: Authority Levels 1-6: Enabled (E) Authority Levels 7-15: Blank (-)
Selection: - or E
Default: Authority Levels 1-5, 14: Enabled (E) Authority Levels 6-13, 15: Blank (-)
Selection: - or E