200 en | ACCESS CONTROL (D9412GV4/D7412GV4) D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
D# RTE Shunt Only?
Use this program item to disable the strike, but still activate the programmed shunt time at a
Request to Enter (RTE) area.
D# REX Shunt Only?
Use this program item to disable the door strike, but activate the programmed D# Shunt Time
upon a request to exit (REX) from an area.
9.3 Event Profile
This programming category is used to determine if events are created for:
– Access Granted and Access Denied
– Door Requests
– Door state changes due to manual (keypad) or automatic scheduled or armed state
changes (skeds/hold open on disarm, normal on armed) operation.
NOTICE!
To Reduce False Alarms, maintain D# Deactivate on Open? as the default (Yes). This helps
prevent the door from bouncing open and causing a false alarm.
Default: No
Selection: Yes or No
Yes Programmed shunt time activates so door can be manually opened.
No RTE automatically activates the programmed strike and shunt time.
NOTICE!
Use this parameter when a user can open a door manually without relying on a token or card
to activate the strike (such as with a push bar).
NOTICE!
When RTE Shunt Only is Yes, RTE Events are not logged, reported, or printed.
Default: No
Selection: Yes or No
Yes Programmed shunt time activates so the door can be manually opened.
No REX automatically activates the programmed strike and shunt time.
NOTICE!
Use this parameter when a user can open a door manually without relying on a token or card
to activate the strike (such as with a push bar).
NOTICE!
When REXShunt Only is Yes, REX Events are not logged, reported, or printed.
NOTICE!
RTE Events require Access Granted to be programmed as Yes.