D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 17
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
3 Panel and Area Wide Parameters
This section has fourteen programming categories.
Phone
Phone Parameters
–Routing
Enhanced Communications
SDI Enhanced Communications
Power Supervision
Printer parameters
RPS Parameters
Miscellaneous
Area Parameters
–Keypad
User Interface
–Function List
Relay Parameters
3.1 Phone
The control panel can dial as many as four different telephone numbers when sending event
reports. Refer to Section 3.3 Routing, page 23 for information about event report routing and
communication protocols.
Phone #
This is the telephone number the control panel dials to contact the central station receiver
when sending event reports. This number is Phone 1 referred to in the prompts in
Section 3.3 Routing, page 23.
The control panel waits for a break in the dial tone after dialing the first digit. If the control
panel must dial a digit (for example, 9) to access an outside line, place a C before the phone
number. The control panel waits 2 sec and does not wait for the dial tone break.
The control panel is programmed with a 7-sec dial tone detect period. When a dial tone is
detected or the waiting period ends, the control panel begins to dial. To extend the dial tone
detect period, place a D before the phone number. To insert a pause during or after dialing,
use C in the number sequence. For example, if the control panel hangs up before it hears the
NOTICE!
When using PSTN telephone lines, program two telephone numbers to meet UL 864
requirements (D9412GV4 and D7412GV4).
Default: Blank
Selection: Up to 24 characters
0 to 9 Numbers 0 through 9
C 3-sec pause
D 7-sec dial-tone detection
# or * Used for the same purpose as pressing this key on a telephone keypad
when manually dialing. For example, an asterisk (*) may be needed to
access your long distance service. Do not use these characters when
pulse dialing.
Blank Control panel dials no phone number.
Programming this item Blank does not disable phone routing. To
disable reporting to this phone, refer to Section 3.3 Routing, page 23.