EasyManua.ls Logo

Bosch D7412GV4 - View Point Status

Bosch D7412GV4
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 65
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
Arms or disarms as an independent area.
Master
Does not allow arming for this area unless all associate areas with the same A# account
number are master exit delay armed or master armed. CHK AREA displays if the associate
areas are not armed. Exception: RPS allows master areas to be armed without all associate
areas being in the armed state.
A master area can be disarmed regardless of the armed state of the other areas in the
account.
Multiple master areas can be programmed in a single account.
Associate
Allows arming and disarming regardless of the armed state of the other areas with the same
A# account number. Use this area type with a master area and associate it by using the same
account number.
Shared
Is not associated to other areas by account number, they are shared panel wide.
Are armed when all Associate areas in the control panel are Master Delay armed.
Are disarmed when at least one Associate area in the control panel is taken out of Master
Delay armed state.
Cannot be individually armed using a passcode, key switch, keyfob, sked, or RPS.
3.10.2 Shared-Area Characteristics
Arming a Shared Area
A shared area arms automatically when all associate areas are armed. As soon as the last
associate area is armed, the shared area automatically begins its arming sequence. Passcode,
key switch, sub-controls, or RPS cannot arm shared areas. To display faulted points at
associate areas, the shared and associate areas must have the same account number.
NOTICE!
CC# Scope affects master arming.
Panel Wide or Account Wide: When arming a master area from a keypad with CC# Scope set
to Panel Wide or Account Wide, all associate areas enters exit delay as soon as the master
area is armed. If there is a shared area within the same account, it begins its exit delay after all
associate areas are armed.
NOTICE!
Using the arming sked (S## Function 1) requires that you first use an arming sked to arm the
associate areas before using an arming sked to arm the master area. Arming master areas with
RPS, Keyswitch, or Auto Close parameters (refer to Section 3.10.4 Open/Close Options,
page 69) occurs before all associate areas are armed
NOTICE!
Keypads assigned to associate areas, when used with shared areas, must have CC# Scope
programmed.
NOTICE!
Arming commands intended for a shared area must be executed on a keypad with Panel Wide
scope by a user with appropriate authority in all Associate areas. Shared areas associate with
all Associate areas regardless of their account assignments. The shares area does not begin to
arm until all Associates finish arming.

Table of Contents

Other manuals for Bosch D7412GV4

Related product manuals