A# Restricted O/C
This item determines if this area can restrict Opening and Closing Report activity.
A Restricted Opening Report refers to the control panel sending an Area Opening Report only
when the area is disarmed after a non-fire alarm.
A Restricted Closing Report refers to the control panel sending a Force Closed Report only
when the area was master armed with Controlled points that were faulted during the arming
sequence. The sequence of reports generated by a restricted closing is: Was Force Armed,
Forced Point, and Force Closed.
A# Perimeter O/C
This item determines if this area can send Perimeter Instant and Perimeter Delay Closing
Reports and normal Opening Reports to the central station. Opening and Closing Windows do
not suppress this event. Refer to Section L## Perimeter O/C, page 113.
3.10.5 Arming Features
A# Two Man Rule
Default: No
Selection: Yes or No
Yes Restrict Opening and Closing Reports for this area. A# Area O/C must
be programmed Yes to generate Restricted Opening and Closing
Reports.
Note:
If a passcode is not required for arming or disarming and this item is
Yes, the area sends only Restricted Opening and Closing Reports. In
this case, Restricted Reports are sent without User ID.
Opening/Closing Window does not affect this report. Windows do not
prevent sending Restricted Opening and Closing Reports from being
sent. Early or late designations are not added to Opening or Closing
Reports when they are sent according to the rules for Restricted
Opening or Closing Reports.
No Do not Restrict Opening and Closing Reports for this area.
Regardless of programming in Authority Levels L## Restricted O/C,
reports are not restricted in this area when this item is programmed as
No.
Note:
Was Force Armed and Forced Close Events can still be sent to the
central station if enabled in Routing when force arming the system.
Default: No
Selection: Yes or No
Yes This area can send Perimeter Opening and Closing Reports.
No This area cannot send Perimeter Opening and Closing Reports.
NOTICE!
This reporting requires ModemIIIa
2
reporting format reporting. Some central station
automation systems cannot process these reports.
Default: No
Selection: Yes or No
Yes Two valid unique passcodes are required to disarm the area.
No A single passcode with a valid authority level can disarm the area.