114 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
3.12.9 Access Control Levels
L## Security Level
Disarm an area by entering a passcode and pressing [ENTER].
Security Level [TOKEN FUNCTION]
When the user presents a token or card at the reader, access is granted only when the user
has the authority to enter the area under certain armed conditions.
L## Disarm Level
L## Function Level
Default: Authority Levels 1-2: Master (M)Authority Levels 3-5: Perimeter
(P)Authority Level 6: Disarmed (D)Authority Levels 7-15: Blank (-)
Selection: M, P, D, or -
M Users have access rights for this area when the area is in any armed
state.
P Users have access rights for this area when the area is Perimeter Armed
or Disarmed but not while the area is Master Armed.
D Users have access rights for this area only while it is disarmed.
- Users do not have access rights to this area.
Default: Authority Levels 1-5: Disarm (D)Authority Levels 6-15: Blank (-)
Selection: I, D, or -
I Users change the Master Armed state and Perimeter Armed state to
Perimeter Instant. The armed state does not change in other areas, and
the armed state does not change if the area is already in the perimeter
instant or disarmed state. User needs access level for Master Armed
(M) state.
D Users change the local area’s Master Armed state and Perimeter Armed
state to the Disarm state. User needs access level for Master Armed (M)
or Perimeter Armed (P) state. All areas within the scope of the keypad
assigned to the D# CC# Scope in the access handler, and areas to
which the user has disarm rights, disarm as programmed.
- Users do not have disarm rights in this area.
NOTICE!
Burglar bells are silenced in the local area when a user disarms with a token or card or
presents the token or card during an alarm. The user must use a passcode to silence a Fire
Bell. Cancel Reports are sent after a valid passcode or token or card silences the bell.
NOTICE!
Opening and Closing Reports are sent to the central station receiver if programmed.
For more information on programming this prompt for a shared area, refer to Section Access
Control Readers Assigned to the Shared Area, page 66.
Default: Authority Level 1: Disarmed (D)Authority Levels 2-15: Blank (-)
Selection: M, D, C, or -
M Activate the custom function assigned to the door in this area while the
area is Master Armed or Disarmed only.
D Activate the custom function assigned to the door in this area while the
area is Disarmed only.