D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 115
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
L## Keyfob Arm/Disarm
Allow a user with this authority level to arm or disarm an area by using their assigned keyfob.
L## Remote Firmware Update
When local authorization is required, only a security user with the Remote Firmware Update
authority enabled shall be able to authorize the update. By default, Remote Firmware Update
authority is only enabled for the Service Passcode (Authority level 15).
C User can activate the custom function assigned to the door in this area
while the area is Master Armed, Perimeter Armed or Disarmed.
- User cannot activate the custom function assigned to the door in this
area.
NOTICE!
When a token or card can also disarm an area, the custom function starts after the area
disarms.
NOTICE!
A user does not require L## Security Level or L## Disarm Level authority to activate a custom
function with a token or card.
NOTICE!
Tokens or cards that are used to execute Custom Functions must have a passcode assigned to
the corresponding User###.
Default: Authority Levels 1-6: Enabled (E)Authority Levels 7-15: Blank (-)
Selection: Blank (-) or Enabled (E)
Blank (-) This function is not authorized for the user who is assigned this
authority level.
Enabled (E) Enabled (E): This function is authorized for the user who is assigned
this authority level.
NOTICE!
Authority Level 15 is reserved for the Service Passcode (User 0). Since the installer is not
allowed a keyfob, authority level 15 shall always be disabled (-).
NOTICE!
Duress operation when disarming is not applicable when using Keyfobs.
Default: Authority Levels 1-6: Enabled (E)Authority Levels 7-15: Blank (-)
Selection: Blank (-) or Enabled (E)
Blank (-) This function is not authorized for the user who is assigned this
authority level.
Enabled (E) Enabled (E): This function is authorized for the user who is assigned
this authority level.