118 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
– Do not use the CHANGE RELAYS? function to toggle relays reserved for special functions.
Special function relays are Area and Panel Wide Relay functions as well as relays assigned
to CC Enter Key Relay and P## Relay Response Type.
– Relay C is always on. Assigning any other relay (1 to 128, A or B) deactivates Relay C so
this output can be used for other functions. When Relay C is programmed for A# Rest
Sensors, power is always supplied from Terminal 8 of the control panel.
– Relay Restoration: The status of relays after programming or resetting the control panel
might restore automatically or require manual restoration. All relays are turned off after
the control panel reboots. The control panel checks certain relay functions every minute
and resumes the correct state after the reset. Other relays must be manually set to the
correct state using the Change Relay Function (COMMAND 54).
3.14.1 Area Relays
Each area can be assigned a unique relay number for each of the events listed in this section.
A# Alarm Bell
This voltage output relay activates and provides 12 VDC output when a Non-fire point (P##
Fire is No) assigned to this area activates an alarm.
For SIA CP-01 Compliance:
Do not set A# Alarm Bell to 0. This feature is required for SIA CP-01 compliance.
A# Fire Bell
This voltage output relay activates and provides 12 VDC output when a Fire point (P## Fire is
Yes) assigned to this area activates an alarm.
Relay functions that resume the proper state within one minute of reboot:
Alarm Bell Perimeter Fault
Summary Fire Summary Trouble
Area Armed Reset Sensors
Fire Bell AC Fail
Summary Alarm Phone Fail
Silent Arm Summary SupBurg
Summary Fire Trouble Communications Fail
Watch Mode Summary SupFire
Relay functions that must be reset manually with Change Relay function (COMMAND 54):
Fail To Close Force Armed
Duress
Default: A
Selection: 0, 1 to 128, A, B, C for D9412GV4
0, 1 to 64, A, B, C for D7412GV4
0, 1 to 24, A, B, or C for D7212GV4
NOTICE!
A# Burg Time and A# Burg Pattern must be programmed in Area or Bell Parameters. This relay
activates according to the bell pattern and remains active until the bell time expires or a valid
passcode is entered. P## Silent Bell must be No for the bell to ring upon alarm.
Default: A
Selection: 0, 1 to 128, A, B, C for D9412GV4
0, 1 to 64, A, B, C for D7412GV4
0, 1 to 24, A, B, or C for D7212GV4