D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 121
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
A# Duress Relay
Activates when a Duress alarm is generated from a keypad assigned to the specified area.
A# Perimeter Fault
Activates when a Controlled Perimeter point (P## Type 1) assigned to the specified area is
faulted, regardless of the armed state of the area. This relay provides a steady output until all
Perimeter points in the area return to normal.
A# Silent Alarm
This relay activates when a point assigned to the specified area and programmed for P##
Silent Bell goes into alarm.
3.14.2 Panel-Wide Relays
The following eleven relay options activate when they occur anywhere in the control panel.
They are not restricted by area boundaries.
AC Failure
Activates when the control panel responds to an AC power failure as programmed in AC Fail
Time in Section 3.6 Power Supervision, page 50. This relay automatically resets when AC power
restores.
Default: 0
Selection: 0, 1 to 128 A, B, or C for D9412GV4
0, 1 to 64, A, B, C for D7412GV4
0, 1 to 24, A, B, or C for D7212GV4
NOTICE!
Burg Time needs a bell period programmed and A# Duress Enable must be Yes. This relay
activates when the Burg Bell starts and deactivates when the Burg Bell time ends. The Burg
Bell pattern has no effect on this relay function.
Default: 0
Selection: 0, 1 to 128 A, B, or C for D9412GV4
0, 1 to 64, A, B, C for D7412GV4
0, 1 to 24, A, B, or C for D7212GV4
NOTICE!
This relay does not activate on interior faults. To detect all area point faults, program all
points as Perimeter points in the area where this relay is assigned.
Default: 0
Selection: 0, 1 to 128 A, B, or C for D9412GV4
0, 1 to 64, A, B, C for D7412GV4
0, 1 to 24, A, B, or C for D7212GV4
NOTICE!
This relay does not activate on interior faults. To detect all area point faults, program all
points as Perimeter points in the area where this relay is assigned.
Default: 0
Selection: 0, 1 to 128 A, B, or C for D9412GV4
0, 1 to 64, A, B, C for D7412GV4
0, 1 to 24, A, B, or C for D7212GV4