108 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
Table 3.18 L## Secure Door-Door Mode Definitions
L## Access Control Level
3.12.7 General Functions
L## Change Display
Change the display (bright display, dim display, and time display) in the area where this
keypad is assigned.
L## Change Time/Date
Change the date and time for the control panel in this area.
L## Change Passcode
Door State Definition
Lock Door Normal Door: When a door is in the Lock Door state, one can initiate the
door sequence using Skeds, CYCLE DOOR?, keypad functions, door
requests, and valid token or card requests.
Secure Door No Access Allowed: When a door is in the Secure Door state, no access
is allowed through the door until it is returned to the Lock Door state.
The Secure Door state includes Sked and keypad functions.
Unlock Door Free Access: When a door is in the Unlocked Door state, the door is
already shunted and the door strike does not prevent the door from
opening. In this state, the user does not need to activate a door request
or present a valid token or card.
Cycle Door Momentary Access: This is a temporary Door Mode in which the door
initiates the door sequence as if a valid token or card was read. This state
occurs using the keypad and remote programming software (RPS). A
sked cannot activate this state.
Default: Authority Levels 1, 15: Enabled (E)Authority Levels 2-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
37 Access Control Level (Menu function only)
This feature is not available with the D7212GV4. Keep the default setting.
NOTICE!
Changing the Access Control Level in any area affects all users and all doors associated with
that level for all areas.
Default: Authority Levels 1, 15: Enabled (E)Authority Levels 2-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
15 Change Display [COMMAND][4][9]
Default: Authority Levels 1, 15: Enabled (E)Authority Levels 2-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
16 Change Time and Date [COMMAND][4][5]
Default: Authority Levels 1, 15: Enabled (E)Authority Levels 2-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
17 Change Passcodes [COMMAND][5][5]