102 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
Use this function to make system programming changes. When enabled, only the Service User
(Authority Level 15) has authority to access this menu. When disabled (set to -), the
programming menu cannot be accessed through the Service User menu.
Keypad Programming of the Keypad Programming Option
D1255
1. Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the DISABLE KP PROG option. Press [ENT].
2. The current keypad programming configuration shows (for example, ALLOWED: YES).
3. Press [ENT] to change the configuration. The keypad reads PRG ALLOWED: followed by
YES or NO.
4. Press [NEXT] or [PREV] to toggle to YES to allow keypad programming or NO to disable
keypad programming, and then press [ENT] to save the changes.
When the keypad reads PARAMETER SAVED, your selection has been configured.
D1260
1. Refer to Section 2.5.1 Keypad Programming Menu, page 12 to access Keypad Programming
and navigate to the Disable Keypad Prog option.
2. The current keypad programming configuration shows (for example, Keypad
Programming Allowed: Yes).
3. Press the Edit softkey to change the area’s status.
4. Press the Yes or No softkey, and then press the Save softkey to save the changes.
5. Press the Save softkey to save the changes.
When the keypad reads Parameter Saved, your selection has been configured.
3.12.6 Authority Level Selections
Use this section to determine which Authority Levels can access keypad functions. If a keypad
command is Enabled and not passcode protected, then it does not need to be Enabled by
Authority Level. All passcode protected keypad commands need to be authorized by user
Authority Level.
Function No. Function Name Alternate Keystroke
N/A Keypad Programming Menu function only
NOTICE!
If at least one area is armed or the control panel is communicating with RPS, you cannot
access keypad programming.
NOTICE!
You can continue using the current programming session. Keypad programming is disabled
once you exit the current session.
NOTICE!
You can continue using the current programming session. Keypad programming is disabled
once you exit the current session.
Authority Level Description
- Disabled: This function is not authorized for the user who is assigned this
authority level.
E Enabled: This function is authorized for the user who is assigned this
authority level.