134 en | Points D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
P## Point Response
Key:
I = Instant alarm
D = Delayed alarm
S = Supervisory
Blank = Audible or visual response
Example of Controlled point:
Point Type = 1
Point Response = 8
Perimeter point with delayed alarm response when armed (opened or shorted) and no
response when disarmed.
Example of 24-hour point:
Point Type = 0
Point Response = 8
P## Entry Delay
Use this option to enter the amount of entry delay time that a user has after faulting a
Controlled point (P## Type 1, 2, 3) with a delayed response (D) (P## Pt Response) of 4, 5, 6,
7, or 8. DISARM NOW appears for the duration of the time programmed when the point is
faulted in the delay condition.
If this time expires before disarming, or if the point is configured with an instant response (I),
an alarm occurs.
With Passcode Length set to a non-zero value, entering a valid Passcode during Entry Delay
disarms the system as soon as the last digit is entered. No other keys are required. When the
Default: Refer to the program record sheet
Selection: 0 - 9, A - F
Default: Refer to the program record sheet
Selection: 5 sec to 600 sec
NOTICE!
The D1255 alternates between DISARM NOW and the point text of the point that caused the
area to enter into entry delay.
NOTICE!
Make entries in 5 sec increments. The programmer does not allow off-increment entries.