D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 77
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
Parameter Setup Requirement:
The Early Ambush timer can be started and stopped only by passcodes with the L## Passcode
Disarm authority.
During an alarm, after the first passcode is entered, the Early Ambush timer still begins. A
Cancel Report might be generated, depending upon the bell time, and the keypad displays
Alarm Silenced normally. If the second valid disarm passcode is entered, the keypads indicate
that the second passcode is valid. Refer to Section Secondary Ambush Code, page 176 for
information about the unique behavior of the two passcodes.
For SIA CP-01 Compliance:
A# Exit Delay Restart
When enabled, this feature activates when a controlled point with delay alarm response
changes from normal to faulted and back to normal during the exit delay. When activated, if
any controlled point in the same area with delay alarm response is faulted, the exit delay time
restarts. The exit delay continues until it expires or the area changes arming states. This
operation can occur only once in an arming cycle.
NOTICE!
To avoid unintended results for the end user of the system:
When a keypad is assigned to an area that has the Early Ambush feature enabled, set the
CC# Scope value to Area Wide.
If an area has A# Two Man Rule set to Yes, do not set A# Early Ambush to Yes.
NOTICE!
This feature is not allowed for use with SIA CP-01 compliant installations.
Default: Yes
Selection: Yes or No
Yes Delay armed points in this area restart the exit delay timer if violated
during the exit delay time.
No Delay armed points continue to count down normally if violated during
the exit delay time.
NOTICE!
This feature must be disabled for UL Line Security/Encryption applications.
NOTICE!
To avoid the possibility of false alarms in Associate areas, do not use the A# Exit Restart
feature in areas with A# Area Type set to Shared.