86 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
CC# Entry Tone
Determines whether this keypad, or any keypad with the same address setting, emits the
entry delay tone. Any Delay point within the area scope of this keypad starts the entry
sequence.
For SIA CP-01 Compliance
CC# Entry Tone can be set to Yes or No.
CC# Exit Tone
Determines whether this keypad, or any keypad with the same address setting, emits the exit
delay tone during the delay arming of an area(s). Any keypad with a scope to arm this area can
initiate the exit tone sequence.
This prompt allows you to manage the tone by keypad. Exit Tone can also be turned off when
programming A# Exit Tone in Area Parameters.
The cadence and pitch of the exit tone increase for the last 10 sec of the exit delay time.
For SIA CP-01 Compliance
CC# Exit Tone can be set to Yes or No.
CC# Arm Now Warning Tone
Default: Yes
Selection: Yes or No
Yes This keypad sounds entry tones.
No This keypad does not sound entry tones.
NOTICE!
This prompt allows you to manage the tone by keypad. Entry Tone can also be turned off when
programming your P## Entry Tone off in Point Index.
NOTICE!
Assign two CCs to the same area so one keypad emits the tone and another does not.
Default: Yes
Selection: Yes or No
Yes This keypad sounds exit tones.
No This keypad does not sound exit tones.
NOTICE!
This SIA CP-01 required feature is not supported on the D720 Series Keypads.
NOTICE!
Assign two CCs to the same area so one keypad emits the tone and another does not. Set one
keypad for CC EXIT TONE = YES, and one to EXIT TONE = NO.
Default: Yes
Selection: Yes or No
Yes This keypad activates a tone and displays PLEASE CLOSE NOW.