157
5.13 Error Codes 5.13 Error Codes
PerformanceLine CX, PerformanceLine,
ActiveLinePlus (BDU350), ActiveLine (BDU310), ActiveLine (BDU250C / 255C)
error code
in DiagnosticTool
error code
in display
Error description, repair
0x550351
550
Tail light is defective, overloaded or interrupted. Light functionality is not
available. Cross inspection by replacing the front/backlights and connec-
tor. Refit the rear light from the drive unit. Delete error code, restart
system.
0x550352
550
Overload due to excessive internal current. Check display and display
cable, connector and base.
0x550353
550
Overload due to excessive current at front and rear light. Light functional-
ity is not available. Cross inspection by replacing the front/backlights and
connector. Disconnect all lights from the bicycle. Delete error code,
restart system.
0x5A00E7
Internal communication error.
0x5A1001
0x5A1002
0x5A1005
0x5B1126
Internal drive unit software error.
0x5A1004
Internal drive unit software error. Check if software updates are available,
and re-flash eBike.
0x5A2001
The configuration of the acceleration sensor is incorrect.
0x5A2002
Communication with acceleration sensor is defective.
0x5A2003
Self-test of acceleration sensor failed.
0x5AA020
Error in engine calibration.
0x5AA02B
Internal sensor error, delayed motor support in the starting phase.
0x5B1030
Internal critical temperature error, motor support is switched off. Switch
off the system so that the drive unit cools down.
0x5B1101
Internal sensor error. Delayed motor support in the starting phase.
0x5B1124
0x5B1125
Internal sensor error, invalid temperature value.
0x5B1322
0x5B1323
Internal sensor error, invalid μc temperature.
5