5.13 Error Codes 5.13 Error Codes
CapacityTester
error code
in DiagnosticTool
error code
in display
Error description, repair
0xA21000
Internal temperature sensor error. Print the diagnostic report, clear the
error, and restart the device. Perform software update.
0xA22100
The temperature at sensor 1 is too high. Allow the device to cool for 30
minutes. Print the diagnostic report, clear the error, and restart the device.
Perform software update.
0xA22200
The temperature at sensor 1 is too low. Print the diagnostic report, clear
the error, and restart the device. Perform software update.
0xA22300
0xA22400
Internal hardware error at sensor 1. Print the diagnostic report, clear the
error, and restart the device. Perform software update.
0xA25100
The temperature at sensor 2 is too high. Print the diagnostic report, clear
the error, and restart the device. Perform software update.
0xA25200
The temperature at sensor 2 is too low. Print the diagnostic report, clear
the error, and restart the device. Perform software update.
0xA25300
0xA25400
Internal hardware error at sensor 2. Print the diagnostic report, clear the
error, and restart the device. Perform software update.
0xA35000
Internal error of fan power supply. Check for fan noise. Print the diagnostic
report, clear the error, and restart the device. Perform software update.
0xA36000
Internal fan error. Check for fan noise. Print the diagnostic report, clear the
error, and restart the device. Perform software update.
0xA37000
Internal error of fan power supply. Check for fan noise. Print the diagnostic
report, clear the error, and restart the device. Perform software update.
0xA38000
Internal fan error. Check for fan noise. Print the diagnostic report, clear the
error, and restart the device. Perform software update.
0xA41000
The voltage of the battery is too high. Reset the battery and check for fault
codes. Check cable and battery connector. Print diagnostics report, per-
form software update for CapacityTester and battery, delete errors and
restart the device.
0xA42000
The battery voltage is too low. Reset the battery and check for fault codes.
Check cable and battery connector. Print diagnostics report, perform
software update for CapacityTester and battery, delete errors and restart
the device.