168
5.13 Error Codes
5.13 Error Codes
CapacityTester
error code
in DiagnosticTool
error code
in display
Error description, repair
0xA43000
Internal discharge error. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
0xA44000
Internal hardware error. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
0xA51000
The measured discharge current is too high. Use a second battery for
swap-testing. Check cable and battery connector. Print the diagnostic
report, clear the error, and restart the device. Perform software update.
0xA52000
The measured discharge current is outside the permissible range. Use a
second rechargeable battery. Check cable and battery connector. Print the
diagnostic report, clear the error, and restart the device. Perform software
update.
0xA53000
Internal hardware error. Use a second rechargeable battery. Print the diag-
nostic report, clear the error, and restart the device. Perform software
update.
0xA54000
Internal hardware error. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
0xA55000
The measured discharge current is too high. Use a second rechargeable
battery. Check cable and battery connector. Print the diagnostic report,
clear the error, and restart the device. Perform software update.
0xA56000
The measured discharge current is outside the permissible range. Use a
second rechargeable battery. Check cable and battery connector. Print the
diagnostic report, clear the error, and restart the device. Perform software
update.
0xA57000
Internal hardware error. Use a second rechargeable battery. Print the diag-
nostic report, clear the error, and restart the device. Perform software
update.
0xA58000
0xA59000
0xA5A000
0xA5B000
0xA5C000
0xA5D000
Internal hardware error. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
0xA61000
USB protocol error. Connect the CapacityTester to another USB port using
another USB cable. Print the diagnostic report, clear the error, and restart
the device. Perform software update.