169
5.13 Error Codes 5.13 Error Codes
CapacityTester
error code
in DiagnosticTool
error code
in display
Error description, repair
0xAA1001
0xAA3001
0xAA3002
0xAA4000
0xAA5000
0xAC0105
0xAC0106
0xAC0107
0xAC0108
0xAC0109
0xAC0110
Internal software error. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
0xAD0000
Incorrect hardware version. Check the software version of the Capacity-
Tester. Print the diagnostic report, clear the error, and restart the device.
Perform software update.
0xAE0000
0xAE1000
Internal communication error. Print the diagnostic report, clear the error,
and restart the device. Perform software update.
0xAE1001
Incorrect software variant. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
0xAE1002
0xAE1003
Incorrect hardware variant. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
0xAE2000
Incorrect battery item number. Print the diagnostic report, clear the error,
and restart the device. Perform software update.
PC_TOOL FAULT
No. 0
No error in the error memory.
PC_TOOL FAULT
No. 1
CAN communication with the connected battery is not possible. Check the
connection between the battery and the CapacityTester, if the battery is
connected correctly, check the battery fault.
PC_TOOL FAULT
No. 2
The selected battery type does not match the connected battery.
Adjust the battery type in DiagnosticTool.
PC_TOOL FAULT
No. 3
CAN communication was interrupted during the measurement. Check the
connection between the battery and the CapacityTester. If the connection
is correct, check the error memory of the battery.
PC_TOOL FAULT
No. 4
The charge level of the battery is too low. The battery must be charged
before starting the measurement.
PC_TOOL FAULT
No. 5
Cooling the CapacityTester does not work properly, restart the system.