5.13 Error Codes
5.13 Error Codes
CapacityTester
error code
in DiagnosticTool
error code
in display
Error description, repair
PC_TOOL FAULT
No. 6
The temperature of the connected battery is too low to start the measure-
ment. Allow the battery to warm slowly to room temperature, restart the
system.
PC_TOOL FAULT
No. 7
The temperature of the connected battery is too high to start the measure-
ment. Slowly allow the battery to cool to room temperature, restart the
system.
PC_TOOL FAULT
No. 8
The user has cancelled the measurement. Restart the system.
PC_TOOL FAULT
No. 9
The connection between the battery and the CapacityTester has been
interrupted, or a fault has occurred in the connected battery. Check the
connection between the battery and the CapacityTester. If the connection
is correct, check the error memory of the battery.
PC_TOOL FAULT
No. 10
The connected battery is connected to a drive unit. For measurement
purposes, the battery may only be connected to the CapacityTester.
PC_TOOL FAULT
No. 11
The connected battery is connected to a charger. For measurement pur-
poses, the battery may only be connected to the CapacityTester.
PC_TOOL FAULT
No. 12
More than one battery is connected to the CapacityTester. Only one battery
can be connected to the CapacityTester for the measurement.
PC_TOOL FAULT
No. 13
Read error of the battery data. Battery data necessary to start the measure-
ment are not available.
PC_TOOL FAULT
No. 14
The temperature of the CapacityTester is too high. Slowly allow the battery
to cool to room temperature, restart the system.
PC_TOOL FAULT
No. 15
The input pack voltage of the CapacityTester has been short circuited
following a ground contact. Check cable and battery connector. Use a
second rechargeable battery. Print the diagnostic report, clear the error,
and restart the device. Perform software update.
PC_TOOL FAULT
No. 16
General internal error of the CapacityTester. Check cable and battery con-
nector. Use a second rechargeable battery.
Print the diagnostic report, clear the error, and restart the device.
Perform software update.
PC_TOOL FAULT
No. 17
General internal battery error. Check cable and battery connector. Check
CapacityTester and battery. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
PC_TOOL FAULT
No. 18
The temperature of the CapacityTester is too low. Allow the battery to
warm slowly to room temperature, restart the system.