5.13 Error Codes
5.13 Error Codes
CapacityTester
error code
in DiagnosticTool
error code
in display
Error description, repair
PC_TOOL FAULT
No. 6
–
The temperature of the connected battery is too low to start the measure-
ment. Allow the battery to warm slowly to room temperature, restart the
system.
PC_TOOL FAULT
No. 7
–
The temperature of the connected battery is too high to start the measure-
ment. Slowly allow the battery to cool to room temperature, restart the
system.
PC_TOOL FAULT
No. 8
– The user has cancelled the measurement. Restart the system.
PC_TOOL FAULT
No. 9
–
The connection between the battery and the CapacityTester has been
interrupted, or a fault has occurred in the connected battery. Check the
connection between the battery and the CapacityTester. If the connection
is correct, check the error memory of the battery.
PC_TOOL FAULT
No. 10
–
The connected battery is connected to a drive unit. For measurement
purposes, the battery may only be connected to the CapacityTester.
PC_TOOL FAULT
No. 11
–
The connected battery is connected to a charger. For measurement pur-
poses, the battery may only be connected to the CapacityTester.
PC_TOOL FAULT
No. 12
–
More than one battery is connected to the CapacityTester. Only one battery
can be connected to the CapacityTester for the measurement.
PC_TOOL FAULT
No. 13
–
Read error of the battery data. Battery data necessary to start the measure-
ment are not available.
PC_TOOL FAULT
No. 14
–
The temperature of the CapacityTester is too high. Slowly allow the battery
to cool to room temperature, restart the system.
PC_TOOL FAULT
No. 15
–
The input pack voltage of the CapacityTester has been short circuited
following a ground contact. Check cable and battery connector. Use a
second rechargeable battery. Print the diagnostic report, clear the error,
and restart the device. Perform software update.
PC_TOOL FAULT
No. 16
–
General internal error of the CapacityTester. Check cable and battery con-
nector. Use a second rechargeable battery.
Print the diagnostic report, clear the error, and restart the device.
Perform software update.
PC_TOOL FAULT
No. 17
–
General internal battery error. Check cable and battery connector. Check
CapacityTester and battery. Print the diagnostic report, clear the error, and
restart the device. Perform software update.
PC_TOOL FAULT
No. 18
–
The temperature of the CapacityTester is too low. Allow the battery to
warm slowly to room temperature, restart the system.