D6412/D4412 Installation Guide
D6412/D4412
10.2.5 DX3010 to D6412/D4412 SDI Bus Wiring Connections
Refer to Table 11 for the SDI bus wiring length requirements.
IMPORTANT
If the DX3010 is to be installed far from the control panel, then the control panel cannot be used to power
the DX3010. An external power supply must be used. See Figure 30 for external power supply
connections.
Power Source #22 AWG (0.8 mm) #18 AWG (1.2 mm)
D6412/D4412 to DX3010 D6412/D4412 40 ft. (12.2 m) 80 ft. (24.4 m)
D6412/D4412 to DX3010 External Power Supply 1000 ft. (305 m) 2000 ft. (610 m)
External Power Supply to DX3010 40 ft. (12.2 m) 80 ft. (24.4 m)
Table 11: DX3010 Wire Lengths
Power down the panel to connect the DX3010 as shown in Figure 29.
Y
G
B
R
NC NOC
8
Y
B
R
G
Yellow
Yellow
Green
Green
Black
Black
Red
DX3010
D6412/D4412
Red
Output Activated State
NC NOC
Output De-activated State
NC NOC
Figure 29: Wiring the DX3010 to the D6412/D4412
Off-board Outputs