Page 51© 2002 Radionics
D6412/D4412 Installation Guide
45349D
D6412/D4412
SDI Devices
Figure 37 shows the common from the External Power Supply Module connected to both the Command
Centers’ common and the common on the Control/Communicator.
Y
G
B
R
D6412/D4412
SDI Device
R B G Y
Red
Black
Yellow
Green
External 12 VDC
Power Supply
+ -
Figure 37: External Power for SDI Devices
12.3 DX4010 RS-232 Serial Interface Module
Radionics’ DX4010 RS-232 Serial Interface Module can be used to connect a standard serial printer, or other
serial devices, to the panel. It can also be used for a RAM IV remote programming direct connection. Refer to
the DX4010 Installation Guide (P/N: 48210) for complete installation, addressing and operating instructions.
DB9 GND
Enable Pins (P1)
Diagnostic LED
Enable Pins (P2)
SER RXTX BUSRXTX
LED ENABLE
DB9 GND
ENABLE
P1
P5
ON
1 2 3 4 5 6
1 2 4
8
16 M
P2
DB9 Connector
Diagnostic LEDs
Address DIP Switches
SDI Bus
Figure 38: DX4010 RS-232 Serial Interface Module