EasyManua.ls Logo

Bosch rexroth IndraDrive Mi KMS03 - DC Bus

Bosch rexroth IndraDrive Mi KMS03
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC bus
Supply unit data - DC bus
Description Symbol Unit
KMV03.1R-
A05K0-P-D7-
ET-NNNN
KMV03.1R-
B0007-P-D7-
ET-NNNN
KMV03.1R-
I01K5-P-D7-
ET-NNNN
KMV03.1R-
W06K0-P-D7-
ET-NNNN
Nominal value of regulated DC
bus voltage
1)
U
DC_nenn
V 750
Capacitance in DC bus
C
DC
mF 2.35
DC‑resistance in DC bus (L+ to
L-)
R
DC
kohm 42.00
Rated power (t > 10 min) at
f
s
= 4 kHz; U
LN_nenn
; control factor
a
0
> 0.8; with mains choke
P
DC_cont
kW 5.00 7.50 1.50 6.00
P
DC_cont
and P
DC_max
vs. mains
input voltage; U
LN
≤ U
LN_nenn
%/V
P
DC_cont(ULN)
= P
DC_cont
× (1 - (400-U
LN
) × 0.0025)
P
DC_cont
and P
DC_max
vs. mains
input voltage; U
LN
> U
LN_nenn
%/V
P
DC_cont
Maximum allowed DC bus power
at U
LN_nenn
; with mains choke
P
DC_max
kW 15.00
Monitoring value maximum DC
bus voltage, switch-off threshold
U
DC_limit_m
ax
V 900
Monitoring value minimum DC bus
voltage, undervoltage threshold
U
DC_limit_mi
n
V 500
Allowed external DC bus
capacitance (nom.) at U
LN_nenn
2)
C
DCext
mF 9.40
Charging time for maximum
external DC bus capacitance
C
DCext
at U
LN_nenn
t
lade_DC_Ce
xt
s 0.70
Latest amendment: 2019-09-04*
1) Only devices with regulated DC bus voltage
2) Use assigned mains choke
Tab. 5-14: KMV - Supply unit data - DC bus
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
99/407
Technical data of the components
R911335703_Edition 04 Bosch Rexroth AG

Table of Contents

Related product manuals