A Servo drives evenly distributed over the entire drive line
B Servo drives evenly distributed at the end of the drive line
C Servo drives evenly distributed starting at 20% of the drive line
P
42V
KCU output X53 load (without cable losses)
P
N3(KCU)
Maximum KCU power consumption from 24V supply
Fig. 7-15: P
N3(KCU)
vs. P
42V
P
N3(KCU)
is a value for the project planning of the 24V supply.
It is impossible to deduce thermal losses in the control cabinet
from the difference between the power P
N3(KCU)
and P
42V
. The
typical losses of KCU are approx. 40% less than the maximum
calculated values.