79
Fine-tune the pressure to get a constant flow from both of the needle channels. The pressure gauge
[13] shows the adjusted pressure in Megapascals (MPa).
If the heating function is used, the lower green LED lights for a moment to indicate that the
temperature setting has been received. The upper red LED is always on when the heater is heating
[14].
The three integrated photocuring LEDs are on a circuit board just underneath the 10 mL syringe
barrel holder around the needle [15].
Pneuma Triaxial Pro is now ready for printing.
After printing, disassemble the print head with the help of the disassembly wrench. Disconnect the
syringe barrels from the pressure connectors and the Luer couplings. Detach the Tygon tubings.
Dispose of or clean the syringe barrels, Luer couplings and tubing. Rinse the pressure connector.