EasyManua.ls Logo

Broadcom NetXtreme - Dmatest; Teste

Broadcom NetXtreme
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 143
Broadcom Confidential and Proprietary
Syntax: cputest [iteration]
Options:
-r<DEC> CPU reset count (def=1)
-f<string> input filename
-n<DEC> iteration (The default iteration is 1. 0 means run forever)
10.129 dmatest
Command: dmatest
Description: DMA Test
Syntax: dmatest [iteration]
Options:
-4 Allocate 4k-aligned buffers
-a<HEX> NIC address (def=00002100)
-d Display DMA info.
-f Force to use 32-bit bus
-h Test high priority
-l<HEX> Length of DATA to do DMA (def=00000400)
-n<DEC> iteration
-o<HEX> Buffer offset (def=00000000)
-w Test low priority
10.130 teste
Command: teste
Description: The command enables tests. It affects nictest, regtest, pkttest, and memtest
commands. The test must starts with test group alphabet (a-d). If no number is
entered, all tests in that group are enabled.
Syntax: teste [<tests> [<tests>…]]
Example: teste a12bc -- Enable test a1, a2, all tests in group b and c