EasyManuals Logo

Broadcom NetXtreme User Manual

Broadcom NetXtreme
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 86
Broadcom Confidential and Proprietary
D
L1 PLL Powerdown Disable
Configure
Description:
Disable / Enable L1 PLL Powerdown
Disable(0)
Disable L1 PLL Powerdown
Enable(1) Enable L1 PLL Powerdown
E
Clock Request
Configure
Description:
Disable / Enable Clock Request
Disable(0)
Disable Clock Request
Enable(1) Enable Clock Request
10.10 seprg
Command: seprg
Description: Program NVRAM and management firmware
Syntax: seprg <file_name>
Input file need to be found in the same location as b57diag.exe.
Options:
-d Do not perform device check
-f<string> filename
-l<HEX> length in bytes (Default = size of input file)
-m Do not restore original MAC address
-n Do not restore original all data at Configuration Block in OTP
-i Do not restore multiple SDID
-o<HEX> offset of serial nvram (def=00000000)
-s Do not restore original Serial Number
-a Program ASF/management firmware
-b As APE UPDATE entry (for –a with APE)
-k<DEC> pad to kilobytes (for –a with APE)
-u Program UMP firmware
-c Skip image CRC check

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom NetXtreme and is the answer not in the manual?

Broadcom NetXtreme Specifications

General IconGeneral
ManufacturerBroadcom
Product LineNetXtreme
CategoryAdapter
Connector TypeRJ45
Supported OSWindows, Linux
FeaturesTCP/IP Offload

Related product manuals