D
L1 PLL Powerdown Disable
Configure
Description:
Disable / Enable L1 PLL Powerdown
Disable(0)
Disable L1 PLL Powerdown
Enable(1) Enable L1 PLL Powerdown
E
Clock Request
Configure
Description:
Disable / Enable Clock Request
Disable(0)
Disable Clock Request
Enable(1) Enable Clock Request
10.10 seprg
Command: seprg
Description: Program NVRAM and management firmware
Syntax: seprg <file_name>
Input file need to be found in the same location as b57diag.exe.
Options:
-d Do not perform device check
-f<string> filename
-l<HEX> length in bytes (Default = size of input file)
-m Do not restore original MAC address
-n Do not restore original all data at Configuration Block in OTP
-i Do not restore multiple SDID
-o<HEX> offset of serial nvram (def=00000000)
-s Do not restore original Serial Number
-a Program ASF/management firmware
-b As APE UPDATE entry (for –a with APE)
-k<DEC> pad to kilobytes (for –a with APE)
-u Program UMP firmware