10.184 smbusrun
Command: smbusrun
Description: Using ‘smbusrun –mxxxxxx’ or smbusrun xxxxxx’ for master read/write.
–xxxx is the message include the slave address.
-for example, if slave address is -0x68, ‘smbusrun 681234’ write 1234 to slave.
‘smbusrun 6919’ read the data from slave.
Using ‘smbusrun –s’ for slave read/write.
Using ‘smbusrun –f’ to set the clock frequency.
Syntax: smbusrun [options]
Options:
-p Add PEC
-s Slave Monitoring SMBus activities
-m<string> Master operation on the bus
-f<DEC> Set clock frequency (def=100000)
10.185 cls
Command: cls
Description: Clear Screen.
Syntax: cls
10.186 loop
Command: loop
Description: loop on command.
Syntax: loop [iteration] <Command> [<parameter> ...]
10.187 dbmode
Command: dbmode
Description: Set DEBUG Mode to On or Off Mode.
Syntax: dbmode on|off