EasyManuals Logo

Broadcom NetXtreme User Manual

Broadcom NetXtreme
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 19
Broadcom Confidential and Proprietary
3.4.4 C4. MII Test
Command: miitest
Function: The function is identical to A2. Control Register Test. Each Register specified in
the configuration contents read only bit and read/write bit defines. The test writing zero and
one into the test bits to insure the read only bits value are not changed, and read/write bits
are changed accordingly.
Default: Enabled.
Default Register table
The test will try to read the register configuration file ‘miireg.txt’ for the register defines. If
the file does not exists, the following table is used:
Offset R/O Mask R/W Mask
0x00 0x0000 0x7180
0x02 0xffff 0x0000
0x03 0xffff 0x0000
0x04 0x0000 0xffff
0x05 0xefff 0x0000
0x06 0x0001 0x0000
0x07 0x0800 0xb7ff
0x08 0xffff 0x0000
0x09 0x0000 0xff00
0x0a 0x7c00 0x0000
0x10 0x0000 0xffbf
0x11 0x3300 0x0000
0x19 0x001f 0x0000
0x1e 0x0000 0xffff
0x1f 0x0000 0xffff
3.4.5 C5. VPD Test
Command: vpdtest
Function: It saves the content of VPD first before perform the test. Once it is done, it writes
one of the five pattern test data, 0xff, 0xaa, 0x55, increment data, or decrement data, into
VPD memory. By default, increment data pattern is used. It writes and reads back the data
for the entire test range, and then restores the original content.
Default: Enabled
3.4.6 C6. ASF Test
Command: asftest

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom NetXtreme and is the answer not in the manual?

Broadcom NetXtreme Specifications

General IconGeneral
ManufacturerBroadcom
Product LineNetXtreme
CategoryAdapter
Connector TypeRJ45
Supported OSWindows, Linux
FeaturesTCP/IP Offload

Related product manuals