Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 148
Broadcom Confidential and Proprietary
Options:
-I Do not perform reset before test
-r<DEC> repeat count for each register test (def=1)
-n<DEC> iteration
10.140 petest
Command: petest
Description: Perform parity error test on a bridge
Syntax: petest <bridge>
10.141 errctrl
Command: errctrl
Description: Configure Error Control Setting
Syntax: errctrl [w|c|a|l|s]
w - Wait on Error
Program will pause and wait for user's action (eng. default)
c - Continue on Error
Program will continue even if the error is detected
a - Abort on Error (Manufacturing default)
Program stops
l - Loop on Error
Program will retry the same test
s - Skip on Error
Program will skip the rest of the present test
10.142 sedvt
Command: sedvt
Description: Perform NVRAM dvt test. When 'init' subcommand is entered, the NVRAM is
initialized into pseudo random pattern. The original content is DESTROYED.
Syntax: sedvt [init]
Options:
-a Access test
-e Erase with reset
-f force
-l<HEX> size (def=00000100)