EasyManuals Logo

Broadcom NetXtreme User Manual

Broadcom NetXtreme
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #180 background imageLoading...
Page #180 background image
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 180
Broadcom Confidential and Proprietary
Options:
-d Change the port to Docking mode
-l Change the port to Laptop mode
-e Enable E-switch functionality.
-f Disable E-switch functionality. This option will prevent PHY
loopback test, external loopback test (pkttest -e), and carrier test from
being performed on both laptop mode and docking mode. By setting
this option the tests are performed only on the default port.
-m internal engineering manual switch and MAC test
10.239 eswitchtest
Command: eswitchtest
Description: Run E-Switch Timer Test.
Syntax: eswitchtest
Options:
-v verbose
10.240 sbfcfg
Command: sbfcfg
Description: Self-boot file configuration
Syntax: sbfcfg <masterfile> [<upgradefile>]
10.241 linkintrtest
Command: linkintrtest
Description: Link Changed Interrupt Test
Syntax: linkintrtest
10.242 ipv6extld
Command: ipv6extld
Description: Load IPv6 Extension Header File

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom NetXtreme and is the answer not in the manual?

Broadcom NetXtreme Specifications

General IconGeneral
ManufacturerBroadcom
Product LineNetXtreme
CategoryAdapter
Connector TypeRJ45
Supported OSWindows, Linux
FeaturesTCP/IP Offload

Related product manuals