-w Test memory via memory_window
10.123 setest
Command: setest
Description: Run NVRAM Test
Syntax: setest [iteration]
Options:
-e extensive test
-d<HEX> ending offset (with -e option) (def=FFFFFFFF)
-n<DEC> iteration
-q quiet mode
-r read only test
-s<HEX> start offset (with -e option) (def=00000000)
10.124 bist
Command: bist
Description: Run BIST. The default iteration is 1. 0 means run forever.
Syntax: bist [iteration]
10.125 nictest
Command: nictest
Description: Run a set of NIC Tests. NIC test can include memory test, serial eeprom test,
interrupt test, packet exchange, MAC registers test, Mii registers test, cpu test, dma test.
This test can to be configured by running “diagcfg”. See “diagcfg” for details. If a “test list”
is not entered below then a set of default tests are run.
Syntax: nictest [test list]
abcd -- runs all tests
b -- runs all test in group B
a3 b1 -- runs test a3 and b1 only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Broadcom NetXtreme and is the answer not in the manual?

Broadcom NetXtreme Specifications

General IconGeneral
ManufacturerBroadcom
Product LineNetXtreme
CategoryAdapter
Connector TypeRJ45
Supported OSWindows, Linux
FeaturesTCP/IP Offload

Related product manuals