Explains safety symbols, hazard levels (DANGER, WARNING, CAUTION), and instructional icons.
Defines the purpose and scope of the HPPR/2 unit, specifying its use in Bruker AVANCE spectrometers.
States that installation and commissioning must be performed by Bruker Service or authorized personnel only.
Provides general safety advice, highlighting awareness of high voltages and safe practices.
Details system owner's obligations for ensuring safe operation, personnel training, and compliance.
Specifies that only trained Bruker personnel are authorized for installation, repair, and dismantling.
Emphasizes the importance of wearing appropriate personal protective equipment during all operations.
Introduces residual risks and hazards identified through risk assessment, requiring adherence to safety instructions.
Details risks associated with electrical hazards, including stored charges, electrical shock, and contact voltage.
Warns about life-threatening risks from high magnetic fields and potential damage to devices.
Addresses dangers from improper handling and disposal of pollutants, stressing compliance with regulations.
Explains various symbols and information signs used in the work area.
Explains symbols on packaging material to ensure correct handling and transport of the device.
Guides on inspecting deliveries for completeness and transport damage, and procedures for reporting issues.
Provides conditions for storing packages to maintain integrity.
Introduces the High Performance Preamplifier version 2 (HPPR/2) and its standard configuration.
Explains the HPPR/2 RF Power Supervision system for monitoring and limiting RF power to protect modules.
Shows the physical connections and wiring diagrams for the HPPR/2 system.
Details wiring diagrams and part lists for the HPPR/2 with up to 4 RF channels.
Shows the front panel layout of the Cover2 module, including the display and status LEDs.
Explains the status indicated by the ERROR and READY LEDs on the HPPR/2 host.
Details the functionality of the LC-Display and the resistive Touch Screen for user interaction.
Explains the different module modes (e.g., dec, obs, lock) and their functions.
Lists the "connected devices" that can be attached to the rear side of the Cover2 module.
Shows the rear panel of the Cover2 module, illustrating various connectors and ports.
Details the RF-OUT, LOCK-OUT, TUNING-IN, HPPR CONTROL, and RJ-45 connectors on the rear.
Covers the module's functionality, including power supply, real-time pulses, and BIS data.
Lists the various preamplifier modules used for Bruker AVANCE NEO systems.
Provides a table of part numbers for different HPPR/2 preamplifier modules based on system frequency.
Describes the operating modes for HPPR/2 XBB, 31P, 13C, and 15N modules.
Provides important technical specifications for AV NEO HPPR/2 modules, including gain and noise figures.
Shows the maximum RF pulse power capability for AV NEO compatible HPPR/2 preamplifier modules.
Introduces the HPPR/2 Baseplate AV4, serving as an interconnect for RF and RGP wiring.
Describes the standard baseplates and their connectors.
Details the typical power consumption of different CRP RF-electronics types and their bias currents.
Introduces the HPPR/2 MRI Active Detuning Module (ADM) and its function in MRI interface modules.
Describes the ADM module, including its block diagram, input pulses, and driver functions.
Guides on troubleshooting ADM-CRP issues, including event messages and diagnostics.
Introduces the HPPR/2 MRI ADM-CRP Module for 1H MRI array cryo probes.
Describes the operating modes for the ADM-CRP module, including CRP Obs and Tune modes.
Provides technical data for the ADM-CRP module, including input signals, wobble, and TMD driver specs.
Introduces the HPPR/2 MRI Baseplate AV4, serving as interconnects for RF and RGP wiring.
Describes the MRI baseplates, their connectors, and internal wiring for 4-channel and 8-channel versions.
Provides instructions for cleaning the device, including before cleaning steps and outer shell cleaning.
Describes how operation failures are displayed on TopSpin and saved in logs.
Explains how hardware failures are reported via event messages on TopSpin and Service Web.
Guides on troubleshooting hardware problems using Service Web, Savelogs, and AqRackServer logs.
Provides instructions on how to report system errors, including information needed for customer service.
Outlines steps for safely shutting down, securing, and dismantling the device before disposal.
Provides environmental information for laboratory and industrial customers within the EU regarding disposal.
Provides general physical data of the HPPR/2 system modules, including weight and dimensions.
Details electrical connection values, including voltages and power consumption for various modules.
Provides contact information for Bruker BioSpin NMR service centers and technical support hotlines.