13.3.1 Inspection activities
The scope of required inspection activities is more limited if your product is registered with BWT and you
use the available options (see table):
BWT Best Water Home app
Download, check and archive device documentation from the app
This is the only way to directly detect and act on necessary actions or mechanical/hydraulic/electrical
problems.
Inspection activities Interval Instruction
for products
WITHOUT
online regis-
tration
Instruction
for products
WITH online
registration
 According to use Required Required
Check brine containers for soiling Every 2 months Required Required
Check for leaks, visual inspection Every 2 months Required Required
Functional test/control unit display Every 2 months Required Not required
Test regenerative consumption depending
on the treated water
Every 2 months Required Not required
Check the setting of the regeneration waste
water system
Every 2 months Required Required
Check the counting function of the water
meter
Every 2 months Required Not required
Test the regeneration process Every 2 months Required Not required
Clean the brine container and the internal
surfaces that come into contact with water
Every 6 months Required Required